Descriere produs: | Product description:
This product set power-on trigger delay, cycle timing delay, high and low level trigger delay and self-locking, point trigger in one, with digital display timing relay module, with accurate delay, 18 kinds of functions are optional, the maximum can be Connected to 220V 10A AC or 30A 10A DC load, widely used in smart home, automation control, product life test, electronic enthusiast design applications. The product is available in 5V, 12V, 24V voltage versions. The delay time is 1-999 seconds and 1-999 minutes. You can select the appropriate voltage version according to your needs.
Features:
This product has 18 function options, the specific functions are as follows:
Power-on (power-on) delay function part:
Function 1 (timed off): The relay is closed when power is on, and the relay is disconnected after the delay time is over (the power will remain disconnected all the time), and the time is between 1 second and 999 seconds (or 1-999 minutes). Tune, if re-powered or a trigger signal to the IN interface (support high/low level trigger, external switch button trigger), interrupt and repeat the above functions;
Function 2 (timed pull-in): The relay is disconnected at power-on, the relay is closed after the delay time is over (the power will remain closed for a long time), and the time is between 1 second and 999 seconds (or 1-999 minutes). Tune, if re-powered or a trigger signal to the IN interface (support high/low level trigger, external switch button trigger), interrupt and repeat the above functions;
Function 3 (timed pull and then disconnect): the relay is closed when power is on, the pull-in time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is broken after the end of the pull-in delay. On, off time (T2) is adjustable from 1 second to 999 seconds (or 1-999 minutes). After the off delay is over, the relay will remain closed, such as powering up again or giving a trigger signal to the IN interface. (Support high/low level trigger, external switch button trigger), interrupt and repeat the above functions;
Function 4 (Timed Disconnect and Retract): The relay is disconnected at power-on, and the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes). After the disconnection delay is over, the relay is sucked. The pull-in time (T2) is adjustable from 1 second to 999 seconds (or 1-999 minutes). The relay will remain open after the pull-in delay expires, such as re-powering or giving a trigger signal to the IN interface. (Support high/low level trigger, external switch button trigger), interrupt and repeat the above functions;
Loop timing function part:
Function 5 (infinite loop timing mode 1): After power-on, the relay is closed, the pull-in time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is disconnected after the pull-in delay ends. The off time (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes). After the off delay is over, the relay again presses the T1 time to infinitely cycle. If the power is turned back on or a trigger signal is sent to the IN interface (supporting high/low level triggering, external switch button triggering), the above functions can be interrupted and repeated once;
Function 6 (infinite loop timing mode 2): The relay is disconnected after power-on, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is closed after the off delay is over. The pull-in time (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes). After the pull-in delay is over, the relay is again turned off by the T1 time, thereby infinitely cycling. If the power is turned back on or a trigger signal is sent to the IN interface (supporting high/low level triggering, external switch button triggering), the above functions can be interrupted and repeated once;
Function 7 (Limited Cycle Timing Mode 1): The relay is energized after power-on, the pull-in time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is disconnected after the pull-in delay ends. The off time (T2) is adjustable from 1 second to 999 seconds (or 1-999 minutes). After the off delay is over, the relay is again pressed by the T1 time, and the number of cycles can be set from 1-999. If the power is turned back on or a trigger signal is sent to the IN interface (supporting high/low level triggering, external switch button triggering), the above functions can be interrupted and repeated once;
Function 8 (limited cycle timing mode 2): The relay is disconnected after power-on, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is closed after the end of the off delay. The pull-in time (T2) is adjustable from 1 second to 999 seconds (or 1-999 minutes). After the pull-in delay is over, the relay is again turned off by the T1 time, and the number of cycles can be set from 1-999. If the power is turned back on or a trigger signal is sent to the IN interface (supporting high/low level triggering, external switch button triggering), the above functions can be interrupted and repeated once;
Trigger delay function part:
Function 9 (trigger timing off 1): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (supports high/low level trigger, external switch button trigger), when there is a trigger signal, the relay sucks The pull-in time is adjustable between 1 second and 999 seconds (or 1-999 minutes). When the delay is over, the relay is disconnected and waits for the next trigger signal. The IN interface trigger is invalid during the delay.
Function 10 (trigger timing pull-in 1): After power-on, the relay does not operate in the off state, waiting for the IN interface trigger signal (supports high/low level trigger, external switch button trigger), when there is a trigger signal, the relay remains Disconnected state and delayed, the disconnection time is adjustable between 1 second and 999 seconds (or 1-999 minutes), the delay is over, the relay is closed (the power will remain stuck all the time), waiting for the next trigger signal The IN interface trigger is invalid during the delay.
Function 11 (trigger timing off 2): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (supports high/low level trigger, external switch button trigger), when there is a trigger signal, the relay sucks The pull-in time is adjustable from 1 second to 999 seconds (or 1-999 minutes). When the delay is over, the relay is disconnected and waits for the next trigger signal. The IN interface trigger is valid during the delay.
Function 12 (trigger timing pull-in 2): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (supporting high/low level trigger, external switch button trigger), when there is a trigger signal, the relay remains Disconnected state and delayed, the disconnection time is adjustable between 1 second and 999 seconds (or 1-999 minutes), the delay is over, the relay is closed (the power will remain stuck all the time), waiting for the next trigger signal The IN interface trigger is valid during the delay.
Function 13 (trigger timing disconnect and re-sink 1): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (support high/low level trigger, external switch button trigger), when there is a trigger signal , the relay remains off and delayed, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), the relay is closed after the disconnection delay, and the pull-in time (T2) ) Adjustable between 1 second and 999 seconds (or 1-999 minutes), the relay will remain open after the pull-in delay expires. Wait for the next trigger signal, the IN interface trigger is invalid during the delay.
Function 14 (trigger timing pull-in and then disconnect 1): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (supports high/low level trigger, external switch button trigger), when there is a trigger signal ,; relay suction combined delay, pull-in time (T1) adjustable between 1 second - 999 seconds (or 1-999 minutes), after the end of the pull-in delay, the relay is disconnected, the off time (T2) is 1 Adjustable between seconds - 999 seconds (or 1-999 minutes), the relay will remain closed after the end of the off delay. Wait for the next trigger signal, the IN interface trigger is invalid during the delay.
Function 15 (trigger timing disconnect and re-sink 2): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (support high/low level trigger, external switch button trigger), when there is a trigger signal , the relay remains off and delayed, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), the relay is closed after the disconnection delay, and the pull-in time (T2) ) Adjustable between 1 second and 999 seconds (or 1-999 minutes), the relay will remain open after the pull-in delay expires. Wait for the next trigger signal, and the IN interface trigger is valid during the delay.
Function 16 (trigger timing pull-in and then disconnect 2): After power-on, the relay does not move in the open state, waiting for the IN interface trigger signal (support high/low level trigger, external switch button trigger), when there is a trigger signal ,; relay suction combined delay, pull-in time (T1) adjustable between 1 second - 999 seconds (or 1-999 minutes), after the end of the pull-in delay, the relay is disconnected, the off time (T2) is 1 Adjustable between seconds - 999 seconds (or 1-999 minutes), the relay will remain closed after the end of the off delay. Wait for the next trigger signal, and the IN interface trigger is valid during the delay.
Function 17 (self-locking relay function): When the IN interface has a trigger signal (support high/low level trigger, external switch button trigger), the relay pulls in, then gives a signal, the relay is disconnected, press 8 Sel key Analog test function.
Function 18: (trigger relay function): When the IN interface has a trigger signal (support high/low level trigger, external switch button trigger), the relay pulls in, the signal disappears, and the relay is disconnected.
Product instructions:
1. The product must be connected to the corresponding DC voltage at the proper terminal, according to the voltage version. Do not connect the wrong power supply or connect in reverse mode the power supply, otherwise the module may be destroyed instantly.
2. Set the product FUNCTION first. Select it with a double-clicking on FS button ('' P '' will flash) then select by single clicking on FS one function from 1-18, every click will increment the number by 1.
3. After selecting the function, double-click the FS button to confirm the selection. It will display '' t '' for time, then adjust the time. Use 8 Sel button (for changing between units, decades or hundreds) and 0-9 Sel button to adjust the time step by step each chosen digit. 8 Sel button is to choose the digit to adjust, 0-9 Sel is to increment the value of the selected digit. Finally double-click the FS button to confirm the chosen time.
4. If there is a Double Time adjustment, after selecting the function, double click the FS button, it will display t1 - select the first desired time, then double click and it will display t2 - select the second desired time (use 8 Sel button and 0-9 Sel button to adjust the time). Finally double-click the FS button to confirm the chosen times and to finish.
5. Delay time 1-999 seconds and 1-999 minutes can be switched by long pressing the FS button, the display A represents a time range of 1-999 seconds, and the display b represents a time range of 1-999 minutes.
6. Functions 17 and 18 do not need to adjust the time. For these two functions, the trigger interface directly controls the relay when there is a trigger signal.
7. Trigger mode selection: When the middle of the jumper is connected with the L terminal, it is a LOW level trigger. At this time, a button switch is connected between the IN terminal and the DC- terminal. When the jumper is connected with the H terminal, It is a HIGH level trigger. At this time, the IN terminal and the DC+ terminal are connected with a push button switch.
8. Press and hold the button 8 Sel for three seconds to turn OFF the digital display. Press and hold for 3 seconds to turn ON the display.
Product parameters:
1. Dimensions: 63.5mm (L) * 38.5mm (W) * 18.5mm (H)
2. Positioning hole size: 58.5mm*33.5mm Hole diameter: 3.1mm
3. Relay load capacity: 220V 10A AC or 30V 10A DC
4. Power: 12V 45mA quiescent current - max. consumption 130mA
|