Descriere produs: | Setul este compus din Modul Receptor RF cu 4 Relee si 2 Radiocomenzi cu 4 butoane. Releele sunt SPDT pentru comanda inchis/deschis a unor consumatori de pana in 250V - 3A. Contactele de actionare sunt separate galvanic total in raport cu montajul. Receptorul se alimenteaza la 12V si consuma maxim 9mA in StBy. Se poate folosi la porti electrice, usi garaj sau in orice fel de automatizari, inclusiv la autoturisme. Modulul invata telecomenzile iar modurile de functionare pot fi programate prin jumpere, asa cum este descris mai jos. Kitul contine modulul si 2 telecomenzi cu bateriile incluse. Pentru o acoperire mai mare, antena se extinde prin gaura laterala a cutiei. Distanta de emisie este minim 10m si maxim 30m. Releele au scoase pe conector toate cele 3 contacte, respectiv COM, NO, NC. Cmportamentele iesirilor de releu se pot stabili prin jumperele 1 si 2.
Main technical
Working temperature:-40°C-+80°C
Sensibility: ≥-105dBm
Frequency: 433MHz
Contact current: ≤3A / ≤250V
Voltage: DC12V
Static current: ≤9mA
Size:74.5×54.5×27mm
Controller capacity: 30 learning & fixed code / 6 rolling code
Learning and clearing code:
Learning & fixed code:
Press "Learning" button on the Receiver, release it until LED light flickers, Receiver
in learning status (LED goes out this moment), then press related button on Remote
control to monitor this Receiver. When LED on Receiver flickers 5 times and then
goes out, it indicates Learning has been done. It can response to up to 30 Remote
control of this mode.
If Remote control is lost and wanting to make it invalid totally, press "Learning" butt-
on (more than 8s) until LED goes out, then Receiver will eliminate all contents auto-
matically. If want to reuse it, just learning one more time again.
Rolling code:
Press "Learning" button on the Receiver, release it until LED light flickers, Receiver
in learning status (LED goes out this moment), then press related button on Remote
control to monitor this Receiver. If LED light is flickering slowly all the time, this ind-
icates First Learning has been done; press "Learning" button again and release it
until LED flickers, this indicates in Second Learning status(LED goes out), press the
same button on Remote control, LED will flickers 5 times quickly, this indicates Lea-
rning has been accomplished. It can response to up to 6 Remote control of this mode.
If Remote control is lost and wanting to make it invalid totally, press "Learning" butt-
on (more than 8s) until LED goes out, then Receiver will eliminate all contents auto-
matically. If want to reuse it, just learning one more time again.
Output Status
A. Signal toggle - jumper inserted on 1
B. Signal latch - jumper inserted on 2
C. Signal momentary - not insert any jumper
D. 2-circuit toggle, 2-circuit momentary - jumper inserted on 1 and 2(301 not equipped with this function)
|