Descriere produs: | Releu auto de putere pentru tensiuni si curenti mari folosit la troliu, macara si alte comenzi de putere mare. Are montare pe suruburi, bobina la 12Vcc, contact SPST-NO de 200A, dimensiuni 69x34x61mm, placare contacte AgNi, , tensiune maxima pe contacte 1000VDC, bobina cu conectare pe mufa. Gauri contacte pentru surub M5, distanta intre gauri 16mm. La temperatura ambianta de 23*C bobina are urmatori parametri: tensiune standard aplicata 12V, rezistenta bobina 24ohm, curent prin bobina la 12V - 500mA, putere disipata la 12V - 6W, tensiune minima de anclansare 9V, tensiune minima de mentinere 1V
Parametri si geometrie in imagini
Contact Data
Contact arrangement: Power Contact:1 Form A
Current rating: 200A
Contact resistance: ≤0.5mΩ(@6V 20A)
Min.Switching load: 12VDC 1A
Max. Switching voltage: 1000VDC
Max. Breaking current: 2000A (450VDC ,1 cycle)
Max. Switching power: 200KW
Load currentcapacity: no smoke, no fire at 8000A (5ms)
Electrical life Test: Ambient temperature 23℃,on:off 0.6s:5.4s, L/R≤1ms
Electrical life - Resistive load 500VDC: 500VDC,200A - 500 cycles
Electrical life - Resistive load 800VDC: 800VDC,200A - 200 cycles
Electrical life - Capacitive load 500VDC: 7.5×104cycles, 500VDC, τ=1ms, inrush 140A
Electrical life - Capacitive load 800VDC: 7.5×104cycles, 800VDC, τ=1ms, inrush 140A
Parameter Data
Mechanical life: 200.000 cycles
Insulation resistance: 1000MΩ (1000VDC)
Dielectric strength between open contacts: 3000VAC 1min 1mA
Dielectric strength between contact and coil: 3000VAC 1min 1mA
The action time (at rated coil voltage): ≤30ms
Release time (at rated coil voltage): ≤10ms
Shock resistance Functional: closed state 490m/s2(50G), disconnected state 98m/s2(10G)
Shock resistance Destructive: > 490m/s2(50G)
Vibration resistance: 10Hz~500Hz 49m/s2(5G)
Ambient temperature: -40℃~+85℃
Ambient humidity: 5%~85% RH
Weight: 200g
External dimension: 69×34×60.8
Features
● 200 amps continuous carry
● Max. Load current capacity:8000A
● 2000 amps interrupte under extreme condition
● Hermetically sealed with hydrogen gas,the arc is not exposed. Be able to use in explosive & harsh environments without oxidation or contamination of contacts
● There is no polarity requirement for load wiring and no polarity requirement for coil drive
● RoHS compliant
NOTES
1. The upper limit of safety temperature is 180℃, and the upper limit of functional temperature is 150℃
2. If the product needs to work for a long time, it is recommended that the upper limit temperature should not exceed 150℃. If the safety temperature exceeds 180℃, the electrical appliance may also catch fire
3. Ambient temperature is 85℃, wire cross sectional area ≥70mm² - (Test conditions for this curve)
4. The data greater than 2000A is the data of short circuit resistance of relay. The relay can guarantee no fire or explosion within this curve. When the current is greater than 3000A, the relay contact may be repulsed by a large current.
Mounting Attention
1. In principle, please do not use it when the relay has fallen down.
2. The relay contacts are sealed and filled with gas. When the contact temperature changes, there is internal gas penetrating characteristic. Relays are forbidden to be used at the temperature beyond our suggestion -40 ℃~85 ℃ for long time.
3. When installing the relay, always use washers to prevent the screws from loosening.
4. Tighten each screw within the rated range given in the outline dimensions. Exceeding the maximum torque may result in breakage.
5. Avoid mounting the relay in strong magnetic fields (near a transformer or magnet) or close to an object that radiates heat.
Electrical Life Attention
1. This relay is a DC high-voltage switch. In its final breakdown mode, it may lose the ability to provide the proper cut-off. Therefore, do not exceed the indicated switching capacity and life.
2. Please treat the relay as a product with limited life and replace it when necessary.
3. The contacts of the relay are polarized. Please follow instructions in the connection schematic when connecting the contacts.
4. Be careful that foreign matter and oils and fats kind, don’t stick to the main terminal parts because it is likely to cause terminal parts to give off unusual heat. Also, please use the following specifications of conductor.
Conductor section
10A Min. 2mm2 nominal cross-sectional area
20A Min. 3mm2 nominal cross-sectional area
40A Min. 10mm2 nominal cross-sectional area
60A Min. 15mm2 nominal cross-sectional area
100A Min. 35mm2 nominal cross-sectional area
150A Min. 45mm2 nominal cross-sectional area
200A Min. 60mm2 nominal cross-sectional area
250A Min. 80mm2 nominal cross-sectional area
300A Min. 100mm2 nominal cross-sectional area
350A Min. 120mm2 nominal cross-sectional area
Coil 200A type Attention
1. Please note that when using a diode, the switching speed may decrease and cause a reduction in cut-off performance, we recommend installing a surge protector varistor.
2. The pick-up voltage and drop-out voltage will change with ambient temperature, please use rated voltage to make sure the relay operate reliable. Don’t exceed maximum coil voltage.
3. Please do not continuously load the maximum voltage on the coil.
Coil 250A and 300A type Attention
4. The 250A and 300A types have built-in dedicated drive circuit, please drive the coil with a quick startup (Built-in one-shot pulse generator circuit).
5. After the ON signal enters the 250A and 300A types, automatic coil current switching occurs after approximately 0.1 seconds.Do not repeatedly turn it OFF within that 0.1seconds interval, as doing so may damage the relay.
|